Adapters Connector Kits Patch Cords & Pigtails Pre - termination Fanout Cable Field Installable Connector FTTH terminal Boxes & Sockets Rack Mount Patch Panel ODF and Distribution Frame Optical Enclosure
                                        Optical PLC Splitter Optical FBT Coupler CWDM Module 4CH/8CH CWDM Mux/Demux Module DWDM Module Optical Attenuator Optical Isolator Optical Circulator Optical Collimator Optical Reflector/Terminator Optical Loopback
Adapters
◇ SC Series ◇ LC Series ◇ FC Series ◇ ST Series ◇ MU Series ◇ E2000 Series ◇ MPO Series ◇ Others
Patch Cords & Pigtails
◇ SC Series ◇ LC Series ◇ FC Series ◇ ST Series ◇ MU Series ◇ E2000 Series ◇ MPO Series ◇ Others
IDC Internal Connection
◇ MPO Patch Panels & Cassettes ◇ High Density MPO Patch Panel & Cassette ◇ MPO Trunk Cable ◇ MPO - LC Patch Cord ◇ MPO - LC Hardness ◇ Uniboot LC Patch Cord ◇ Pull - tap MPO ◇ Pull - tap LC Patch cord ◇ Polarity Switchable MPO Patch Cord ◇ Polarity Switchable LC Patch Cord ◇ CS/SN series
Features
· Good mechanical and environmental characteristics.
· The strippability characteristics of each fiber meet the relevant standards or customer requirements.
· The twist characteristics of fiber ribbon meet the relevant standards and customer requirements.
· The characteristics of single-mode and multi-mode fiber used in Fiber ribbon meet the requirements of relevant international and national standards.
· Full chromatogram is adopted. The color meets the requirements in GB 6995.2 and takes turns as following: blue, orange, green, brown, gray, white, red, black, yellow, violet, pink, turqu oise, or other contracted color.
· Meet various requirements of market and clients.
Application
· Used as the basic element of optical-fiber-ribbon indoor cable.
· Directly used in optical connections of equipments and apparatus in some special environment.
Options
· Fiber Type: G.652, G.655, G.657 single-mode fiber, A1a or A1b mulit-mode fiber, or other types of fiber.
· Fiber Count: Total number of fiber in the ribbon.
· Delivery Length: 1KM or 2KM or other contracted length.
· Other Requirements: Basic requirements of fiber ribbon and other contracted individual requirements.
Specifications
| Fiber Count | Width(w) (mm)  | Thickness(t) (mm)  | Horizontal Space Between Adjacent Fibers(d) (mm)  | Horizontal Space Between End Fibers(d) (mm)  | Planarity(p) (um)  | 
Optical Fiber Ribbon  | |||||
2  | ≤0.700  | ≤0.400  | ≤0.280  | ≤0.280  | -  | 
4  | ≤1.220  | ≤0.400  | ≤0.280  | ≤0.835  | ≤35  | 
6  | ≤1.770  | ≤0.400  | ≤0.280  | ≤1.385  | ≤35  | 
8  | ≤2.300  | ≤0.400  | ≤0.300  | ≤1.920  | ≤35  | 
10  | ≤2.850  | ≤0.400  | ≤0.300  | ≤2.450  | ≤35  | 
12  | ≤3.400  | ≤0.400  | ≤0.300  | ≤2.950  | ≤35  |