Adapters Connector Kits Patch Cords & Pigtails Pre - termination Fanout Cable Field Installable Connector FTTH terminal Boxes & Sockets Rack Mount Patch Panel ODF and Distribution Frame Optical Enclosure
Optical PLC Splitter Optical FBT Coupler CWDM Module 4CH/8CH CWDM Mux/Demux Module DWDM Module Optical Attenuator Optical Isolator Optical Circulator Optical Collimator Optical Reflector/Terminator Optical Loopback
Adapters
◇ SC Series ◇ LC Series ◇ FC Series ◇ ST Series ◇ MU Series ◇ E2000 Series ◇ MPO Series ◇ Others
Patch Cords & Pigtails
◇ SC Series ◇ LC Series ◇ FC Series ◇ ST Series ◇ MU Series ◇ E2000 Series ◇ MPO Series ◇ Others
IDC Internal Connection
◇ MPO Patch Panels & Cassettes ◇ High Density MPO Patch Panel & Cassette ◇ MPO Trunk Cable ◇ MPO - LC Patch Cord ◇ MPO - LC Hardness ◇ Uniboot LC Patch Cord ◇ Pull - tap MPO ◇ Pull - tap LC Patch cord ◇ Polarity Switchable MPO Patch Cord ◇ Polarity Switchable LC Patch Cord ◇ CS/SN series
Features
· Good mechanical and environmental characteristics.
· The strippability characteristics of each fiber meet the relevant standards or customer requirements.
· The twist characteristics of fiber ribbon meet the relevant standards and customer requirements.
· The characteristics of single-mode and multi-mode fiber used in Fiber ribbon meet the requirements of relevant international and national standards.
· Full chromatogram is adopted. The color meets the requirements in GB 6995.2 and takes turns as following: blue, orange, green, brown, gray, white, red, black, yellow, violet, pink, turqu oise, or other contracted color.
· Meet various requirements of market and clients.
Application
· Used as the basic element of optical-fiber-ribbon indoor cable.
· Directly used in optical connections of equipments and apparatus in some special environment.
Options
· Fiber Type: G.652, G.655, G.657 single-mode fiber, A1a or A1b mulit-mode fiber, or other types of fiber.
· Fiber Count: Total number of fiber in the ribbon.
· Delivery Length: 1KM or 2KM or other contracted length.
· Other Requirements: Basic requirements of fiber ribbon and other contracted individual requirements.
Specifications
Fiber Count | Width(w) (mm) | Thickness(t) (mm) | Horizontal Space Between Adjacent Fibers(d) (mm) | Horizontal Space Between End Fibers(d) (mm) | Planarity(p) (um) |
Optical Fiber Ribbon | |||||
2 | ≤0.700 | ≤0.400 | ≤0.280 | ≤0.280 | - |
4 | ≤1.220 | ≤0.400 | ≤0.280 | ≤0.835 | ≤35 |
6 | ≤1.770 | ≤0.400 | ≤0.280 | ≤1.385 | ≤35 |
8 | ≤2.300 | ≤0.400 | ≤0.300 | ≤1.920 | ≤35 |
10 | ≤2.850 | ≤0.400 | ≤0.300 | ≤2.450 | ≤35 |
12 | ≤3.400 | ≤0.400 | ≤0.300 | ≤2.950 | ≤35 |